Dopplers in Urological Surgery
The VTI 8 MHz Surgical Doppler System and the VTI 20 MHz Microvascular Doppler System are used by urological surgeons who want an audio blood flow detector to identify and assess critical blood vessels in a portable, easy-to-use format. The sterile, single-use probe offers the surgeon substantial efficiency and convenience while helping to ensure patients' safety.
The VTI 8 MHz Surgical Doppler System is used to guide dissection/isolation of the renal hilum and aberrant vasculature in laparoscopic and robotic radical and partial nephrectomy, confirm parenchymal ischemia before resection in partial nephrectomy, and identify crossing vessels during pyeloplasty.
The VTI 20 MHz Microvascular Doppler System offers guidance in open, laparoscopic and robotic microvascular procedures. Male infertility specialists recognize its value in identifying and preserving the testicular artery while allowing the veins to be safely tied off in varicocele repair.
Microvascular Procedures
- Varicocele ligation
- Penile reconstruction
Laparoscopic & Robotic Procedures
- Varicocele ligation
- Pyeloplasty
- Radical nephrectomy
- Partial nephrectomy
Doppler Uses
- Identifies and preserves the testicular artery
- Confirms renal parenchymal ischemis after clamping in partial nephrectomy
- Identifies and guides dissection of aberrant vasculature in radical and partial nephrectomy
- Verifies technical results of anastamoses
References
- Varicocele: Treatment
Wesley M White, MD, et al. eMedicine. WebMD. 28 July 2009. - The systematic use of intraoperative vascular Doppler ultrasound during microsurgical subinguinal varicocelectomy improves precise identification and preservation of testicular blood supply.
Cocuzza M., et al. Fertility and Sterility. 2010 May 1;93(7):2396-9. Epub. 2009 Mar 6. - Laparoscopic Doppler technology: applications in laparoscopic pyeloplasty and radical and partial nephrectomy.
Hyams ES, et al. Urology.
2008 May;71(5):952-6. - The use of a Doppler ultrasound probe during vascular dissection in laparoscopic renal surgery.
Sethi AS, et al. J Endourol. 2009 Sep;23(9):1377-82.
"The VTI Doppler is an important instrument for the urologist performing microvascular surgery. It is routinely used for all my varicocele repairs."
-Larry Lipshultz, MD
Urology Videos
- Doppler for Robotic Assisted Microsurgical Neurolysis of the Spermatic Cord
Sijo Joseph Parekattil, MD, Co-Director of Robotic Surgery, Director, Male Infertility & Microsurgery, University of Florida, Gainesville
- Doppler for Robotic Retroperitoneal Partial nephrectomy
- Doppler for Robotic Complex Renal Hilum
- Doppler for Robotic Pyeloplasty
- Laparoscopic Doppler Probe for Partial Nephrectomy
- Laparoscopic Doppler Probe for Robotic Nephroureterectomy
Michael Stifelman, M.D., Director of Robotic Surgery, NYU Langone Medical Center